soft starter for asynchronous motor, Altistart 48, 96A, 208..690V, 22..90kW
ATS48C11Y
Range of Product | Altistart 48 |
Product or Component Type | Soft starter |
product destination | Asynchronous motors |
Product Specific Application | Heavy duty industry and pumps |
Device short name | ATS48 |
Utilisation category | AC-53A |
Ue power supply voltage | 208…690 V – 15…10 % |
power supply frequency | 50…60 Hz – 5…5 % |
Motor power kW | 22 kW 230 V for severe applications |
30 kW 230 V for standard applications | |
45 kW 400 V for severe applications | |
45 kW 440 V for severe applications | |
55 kW 400 V for standard applications | |
55 kW 440 V for standard applications | |
55 kW 500 V for severe applications | |
55 kW 525 V for severe applications | |
75 kW 500 V for standard applications | |
75 kW 525 V for standard applications | |
75 kW 660 V for severe applications | |
75 kW 690 V for severe applications | |
90 kW 660 V for standard applications | |
90 kW 690 V for standard applications | |
Maximum Horse Power Rating | 100 hp 575 V for standard applications |
25 hp 208 V for severe applications | |
30 hp 208 V for standard applications | |
30 hp 230 V for severe applications | |
40 hp 230 V for standard applications | |
60 hp 460 V for severe applications | |
75 hp 460 V for standard applications | |
75 hp 575 V for severe applications |
Device connection | In the motor supply line |
Protection type | Phase failure line |
Thermal protection motor | |
Thermal protection starter | |
Standards | EN/IEC 60947-4-2 |
Product Certifications | GOST |
TCF | |
CCC | |
SEPRO | |
NOM 117 | |
C-tick | |
CSA | |
UL | |
DNV | |
marking | CE |
Discrete input number | 5 |
Discrete input type | PTC, 750 Ohm 77 掳F (25 掳C) |
Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm | |
Discrete input logic | Positive logic Stop, Run, LI3, LI4 < 5 V <= 2 mA > 11 V, >= 5 mA |
Minimum switching current | 10 mA 6 V DC relay outputs |
Discrete output number | 2 |
Discrete output type | LO1) logic output 0 V common configurable |
LO2) logic output 0 V common configurable | |
R1) relay outputs fault relay NO | |
R2) relay outputs end of starting relay NO | |
R3) relay outputs motor powered NO | |
Analogue output type | Current output AO 0-20 mA or 4-20 mA 500 Ohm |
Communication Port Protocol | Modbus |
Connector Type | 1 RJ45 |
Communication data link | Serial |
Physical interface | RS485 multidrop |
Transmission Rate | 4800, 9600 or 19200 bps |
Function Available | External bypass (optional) |
Operating position | Vertical +/- 10 degree |
Height | 11.42 in (290 mm) |
Width | 7.48 in (190 mm) |
Depth | 9.25 in (235 mm) |
Net Weight | 18.30 lb(US) (8.3 kg) |
Electromagnetic compatibility | Conducted and radiated emissions level A IEC 60947-4-2 |
Conducted and radiated emissions level B IEC 60947-4-2 | |
Damped oscillating waves level 3 IEC 61000-4-12 | |
Electrostatic discharge level 3 IEC 61000-4-2 | |
Immunity to electrical transients level 4 IEC 61000-4-4 | |
Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 | |
Voltage/current impulse level 3 IEC 61000-4-5 | |
Relative humidity | 0…95 % without condensation or dripping water EN/IEC 60068-2-3 |
Ambient air temperature for operation | 104…140 °F (40…60 °C) with current derating of 2 % per °C) |
14…104 °F (-10…40 °C) without derating) | |
Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Operating altitude | <= 3280.84 ft (1000 m) without derating |
> 3280.84…6561.68 ft (> 1000…2000 m) with current derating of 2.2 % per additional 100 m | |
Ordering and shipping details | |
Category | US1CP1G22579 |
Discount Schedule | CP1G |
GTIN | 3.38911E+12 |
Returnability | Yes |
Country of origin | US |