Part Nr: 6SY7010-0AB02 Siemens Thyristor Module

Brand:   Type:
State:  

Buy at DCS-Centers.com, Best price and Big Stock.

6SY7010-0AB02 Technical Parameters

Basic Information

  • Model: 6SY7010-0AB02
  • Type: Layer A Thyristor Block, built-in RC snubber circuit, for infeed / regenerative unit
  • Brand / Origin: Siemens, Made in Germany
  • Applicable Equipment: SIMOVERT MV, 6SE70 / 6RA70 series high-power inverter and DC drive units (400V class)
  • Status: EOL (End of Life), original spare parts available for ordering

Electrical Rated Parameters (Official & Measured, 25℃, Water Cooling)

Parameter Value Unit Remarks
Rated 3-phase AC Input Voltage 380~460 V 50/60Hz
Rated On-state RMS Current 1180 A Continuous, water cooling
Repetitive Peak Off-state Voltage 1600 V Repetitive, 50Hz
Repetitive Peak Reverse Voltage 1600 V Repetitive, 50Hz
Non-repetitive Surge Current 1420 A (Peak) 50Hz half-wave, ℃
Gate Trigger Current ≤2.0 A DC
Gate Trigger Voltage ≤3.6 V DC
Holding Current 1200~1400 mA Typical: 1300mA
On-state Voltage Drop ≤1.9 V At , typical: 1.8V
Snubber Circuit Built-in RC Original integrated dv/dt suppression

Environmental & Mechanical Parameters (Official)

  • Operating Junction Temperature : -40 ~ +125 ℃ (Long-term)
  • Storage Temperature: -55 ~ +150 ℃
  • Cooling Method: Water cooling (standard, flow ≥8L/min); Forced air cooling (optional, 20% derating)
  • Weight: 26.5 kg (±0.5kg)
  • Dimensions (W×H×D): 730 × 380 × 450 mm
  • Protection Class: IP20 (Module body)
  • Insulation Withstand Voltage: AC 2500V / 1min (Module to heat sink)

Key Difference vs 6SY7010-0AB01

  • 6SY7010-0AB01: , Surge 1230A
  • 6SY7010-0AB02: , Surge 1420A

    Same voltage and package, current capacity increased by 15%.

Compatible Replacement Models

  • 6SY7010-0AB02 → 6SY7010-0AB15 (500~575V, 1180A)
  • 6SY7010-0AB02 → 6SY7010-0AB31 (660~690V, 1285A)

Application Limitations

  1. Only applicable for Siemens original rectifier / regenerative units; cannot directly replace non-original modules.
  2. Water cooling requirement: Inlet temperature ≤35℃, pressure 0.3~0.6MPa, flow ≥8L/min.
  3. Junction temperature strictly not to exceed 125℃, otherwise irreversible aging occurs.

parts photo album​

6SY7010-0AB02 Siemens Thyristor Module

Click edit button to change this text. Lorem ipsum dolor sit amet consectetur adipiscing elit dolor
Hot Sell

Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Customer feedback
Rated 9 out of 10

People who viewed this item also viewed

Made in Germany

Click edit button to change this text. Lorem ipsum dolor sit amet consectetur adipiscing elit dolor

6SY7010-0AB02 Siemens Thyristor Module

Welcome to send your RFQ

Please provide your detailed information below, we will contact you within 24 hours and arrange for a business manager to provide you with a quotation