Variable speed drive, Altivar Process ATV600, ATV630, 315kW/500 hp, 380…480 V,
IP00
| Range of product | Altivar Process ATV600 |
|---|---|
| Product or component type | Variable speed drive |
| Product specific application | Process and utilities |
| Device short name | ATV630 |
| variant | Standard version |
| Product destination | Asynchronous motors Synchronous motors |
| EMC filter | Integrated with 50 m conforming to EN/IEC 61800-3 category C3 |
| IP degree of protection | IP00 conforming to IEC 61800-5-1 IP00 conforming to IEC 60529 IP21 (with kit VW3A9113) conforming to IEC 61800-5-1 IP21 (with kit VW3A9113) conforming to IEC 60529 |
| [Us] rated supply voltage | 380…480 V |
| Type of cooling | Forced convection |
| supply frequency | 50…60 Hz – 5…5 % |
| [Us] rated supply voltage | 380…480 V – 15…10 % |
| motor power kW | 315 kW (normal duty) 250 kW (heavy duty) |
| motor power hp | 500 hp normal duty 400 hp heavy duty |
| line current | 569 A at 380 V (normal duty) 461 A at 480 V (normal duty) 457 A at 380 V (heavy duty) 375 A at 480 V (heavy duty) |
| Prospective line Isc | 50 kA |
| apparent power | 351 kVA at 480 V (normal duty) 286 kVA at 480 V (heavy duty) |
| continuous output current | 616 A at 2.5 kHz for normal duty 481 A at 2.5 kHz for heavy duty |
| maximum transient current | 678 A during 60 s (normal duty) 722 A during 60 s (heavy duty) |
| Asynchronous motor control profile | Constant torque standard Optimized torque mode Variable torque standard |
| Synchronous motor control profile | Permanent magnet motor Synchronous reluctance motor |
| Speed drive output frequency | 0.1…500 Hz |
| Nominal switching frequency | 2.5 kHz |
| switching frequency | 2.5…8 kHz with derating factor 2…8 kHz adjustable |
| safety function | STO (safe torque off) SIL 3 |
| Discrete input logic | 16 preset speeds |
| Communication port protocol | Modbus serial Ethernet Modbus TCP |
| option card | Slot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link Communication module, BACnet MS/TP Communication module, Ethernet Powerlink |
| Mounting mode | Wall mount |
|---|---|
| Network number of phases | 3 phases |
| Discrete output number | 0 |
| discrete output type | Relay outputs R1A, R1B, R1C 250 V AC 3000 mA Relay outputs R1A, R1B, R1C 30 V DC 3000 mA Relay outputs R2A, R2C 250 V AC 5000 mA Relay outputs R2A, R2C 30 V DC 5000 mA Relay outputs R3A, R3C 250 V AC 5000 mA Relay outputs R3A, R3C 30 V DC 5000 mA |
| Output voltage | <= power supply voltage |
| permissible temporary current boost | 1.1 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty) |
| Motor slip compensation | Adjustable Can be suppressed Automatic whatever the load Not available in permanent magnet motor law |
| Acceleration and deceleration ramps | Linear adjustable separately from 0.01…9999 s |
| Physical interface | Ethernet 2-wire RS 485 |
| Braking to standstill | By DC injection |