Main |
Range of product |
Easy Altivar 610 |
Product or component type |
Variable speed drive |
Product specific application |
Fan, pump, compressor, conveyor |
Device short name |
ATV610 |
variant |
Standard version |
Product destination |
Asynchronous motors |
Synchronous motors |
Mounting mode |
Cabinet mount |
EMC filter |
Integrated conforming to IEC 61800-3 category C3 with 50 m |
IP degree of protection |
IP20 |
Type of cooling |
Forced convection |
Supply frequency |
50…60 Hz +/-5 % |
Network number of phases |
3 phases |
[Us] rated supply voltage |
380…460 V – 15…10 % |
Motor power kW |
75 kW for normal duty |
55 kW for heavy duty |
Motor power hp |
100 hp for normal duty |
75 hp for heavy duty |
Line current |
147.9 A at 380 V (normal duty) |
130.2 A at 460 V (normal duty) |
115.8 A at 380 V (heavy duty) |
101.7 A at 460 V (heavy duty) |
Prospective line Isc |
22 kA |
Apparent power |
103.7 kVA at 460 V (normal duty) |
81.0 kVA at 460 V (heavy duty) |
Continuous output current |
145 A at 2.5 kHz for normal duty |
106 A at 2.5 kHz for heavy duty |
Maximum transient current |
160 A during 60 s (normal duty) |
159 A during 60 s (heavy duty) |
Asynchronous motor control profile |
Constant torque standard |
Optimized torque mode |
Variable torque standard |
Output frequency |
0.1…500 Hz |
Nominal switching frequency |
2.5 kHz |
Switching frequency |
1…8 kHz adjustable |
number of preset speeds |
16 preset speeds |
Communication port protocol |
Modbus serial |
Option card |
Slot A: communication card, Profibus DP V1 |
Slot A: digital or analog I/O extension card |
Slot A: relay output card |
Complementary |
Output voltage |
<= power supply voltage |
Motor slip compensation |
Automatic whatever the load |
Can be suppressed |
Adjustable |
Not available in permanent magnet motor law |
Acceleration and deceleration ramps |
S, U or customized |
Linear adjustable separately from 0.01 to 9000 s |
Braking to standstill |
By DC injection |
Protection type |
Thermal protection: motor |
Motor phase break: motor |
Thermal protection: drive |
Overheating: drive |
Overcurrent between output phases and earth: drive |
Overload of output voltage: drive |
Short-circuit protection: drive |
Motor phase break: drive |
Overvoltages on the DC bus: drive |
Line supply overvoltage: drive |
Line supply undervoltage: drive |
Line supply phase loss: drive |
Overspeed: drive |
Break on the control circuit: drive |
Frequency resolution |
Display unit: 0.1 Hz |
Analog input: 0.012/50 Hz |
Electrical connection |
Control, screw terminal: 0.5…1.5 mm² |
Line side, screw terminal: 95…120 mm² |
Motor, screw terminal: 95…120 mm² |
Connector type |
1 RJ45 (on the remote graphic terminal) for Modbus serial |
Physical interface |
2-wire RS 485 for Modbus serial |
Transmission frame |
RTU for Modbus serial |
Transmission rate |
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
Type of polarization |
No impedance for Modbus serial |
Number of addresses |
1…247 for Modbus serial |
Method of access |
Slave |
Supply |
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection |
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection |
Local signalling |
2 LEDs for local diagnostic |
1 LED (yellow) for embedded communication status |
2 LEDs (dual colour) for communication module status |
1 LED (red) for presence of voltage |
Width |
290 mm |
Height |
762 mm |
922 mm with EMC plate |
Depth |
323 mm |
Net weight |
53 kg |
Analogue input number |
3 |
Analogue input type |
AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits |
AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits |
AI2, AI3 software-configurable temperature probe or water level sensor |
Discrete input number |
6 |
Discrete input type |
DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm |
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) |
Input compatibility |
DI1…DI6: logic input level 1 PLC conforming to IEC 61131-2 |
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68 |
Discrete input logic |
Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) |
Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) |
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1) |
Analogue output number |
2 |
Analogue output type |
Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits |
Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits |
Sampling duration |
5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input |
2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input |
5 ms +/- 1 ms (DI5, DI6)configurable – pulse input |
10 ms +/- 1 ms (AQ1, AQ2) – analog output |
Accuracy |
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input |
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
Linearity error |
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input |
AQ1, AQ2: +/- 0.2 % for analog output |
Relay output number |
3 |
Relay output type |
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles |
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles |
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
Refresh time |
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
Minimum switching current |
Relay output R1, R2, R3: 5 mA at 24 V DC |
Maximum switching current |
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC |
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC |
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC |
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
Isolation |
Between power and control terminals |
Insulation resistance |
> 1 MOhm 500 V DC for 1 minute to earth |
Environment |
Noise level |
78 dB conforming to 86/188/EEC |
Power dissipation in W |
1460 W(forced convection) at 380 V, switching frequency 2.5 kHz |
177 W(natural convection) at 380 V, switching frequency 2.5 kHz |
Volume of cooling air |
295 m3/h |
Operating position |
Vertical +/- 10 degree |
Electromagnetic compatibility |
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 |
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 |
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 |
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 |
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
Pollution degree |
2 conforming to IEC 61800-5-1 |
Vibration resistance |
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 |
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
Shock resistance |
15 gn for 11 ms conforming to IEC 60068-2-27 |
Relative humidity |
5…95 % without condensation conforming to IEC 60068-2-3 |
Ambient air temperature for operation |
-15…45 °C (without derating) |
45…60 °C (with derating factor) |
Ambient air temperature for storage |
-40…70 °C |
Operating altitude |
<= 1000 m without derating |
1000…4800 m with current derating 1 % per 100 m |
Environmental characteristic |
Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 |
Dust pollution resistance class 3S3 conforming to IEC 60721-3-3 |
Standards |
IEC 61800-3 |
Environment 2 category C3 IEC 61800-3 |
IEC 61800-5-1 |
IEC 60721-3 |
Marking |
CE |